NSN 4320-01-268-4448
Part Details | CENTRIFUGAL PUMP UNIT
4320-01-268-4448 An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.
Alternate Parts: MILP17454, MIL-P-17454, MILP17454VM, MIL-P-17454VM, 4320-01-268-4448, 01-268-4448, 4320012684448, 012684448
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 43 | NOV 30, 1987 | 01-268-4448 | 17988 ( PUMP UNIT, CENTRIFUGAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4320-01-268-4448
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MIL-P-17454 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-P-17454VM | 03950 | NAVAL INVENTORY CONTROL POINTMECHANICSBURG |
Technical Data | NSN 4320-01-268-4448
| Characteristic | Specifications |
|---|---|
| MAXIMUM DISCHARGE FLOW RATE | 200.0 GALLONS PER MINUTE |
| TOTAL HEAD | 70.000 FEET |
| SUCTION LIFT | 20.000 FEET |
| CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
| MEDIA FOR WHICH DESIGNED | WATER, SALT |
| PUMP QUANTITY | 1 |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| CURRENT TYPE | AC |
| VOLTAGE IN VOLTS | 440.0 |
| FREQUENCY IN HERTZ | 60.0 |
| PHASE | THREE |
| INCLOSURE TYPE | FULLY INCLOSED |
| ENVIRONMENTAL PROTECTION | SUBMERSIBLE |
| SPECIAL FEATURES | ITEMS ARE BEING CODED AS CRITICAL TO INSURE SOURCE INSPECTION WILL BE PERFORMED AT THE POINT OF MANUFACTURE, PRIOR TO MATERIAL RECEIPT BY THE US NAVY OR OTHER DOD COMPONENTS. THESE ITEMS ARE PIECE PARTS OR END ITEMS IN SUPPORT OF VITAL MILITARY HARDWARE NECESSARY TO SUSTAIN THE SUCCESSFUL MISSION OF THE SHIPS, SUBMARINES, AND SHORE STATIONS OF THE US NAVY. CRITICAL FEATURES INCLUDING, BUT NOT LIMITED TO, DIMENSIONS, TOLERANCES/CLEARANCES, ELECTRONIC CHARACTERISTICS, AND METALLURGICAL PROPERTIES WILL BESPECIFIED FOR GOVERNMENT Q AR (QUALITY ASSURANCE REPRESENTATIVES) TO INSURE THE HIGHEST POSSIBLE DEGREE OF QUALITY AND RELIABILITY OF THESE PARTS BEING DELIVERED UNDER NAVICP CONTRACTS |
| NONDEFINITIVE SPEC/STD DATA | 1 CLASS |
| DEPARTURE FROM CITED DOCUMENT | MAGNETIC PERMEABILITY SHALL NOT EXCEED 2.0 AFTER FABRICATION |
| CRITICALITY CODE JUSTIFICATION | FEAT |