NSN 4920-01-468-3017
Part Details | PLASMA SPRAY MASK
4920-01-468-3017 A item usually metallic with an open pattern, mounted on a part(s) to cover selected areas during a metal coating (deposition) process. The item may have attaching hardware consisting of a base assembly, knob, spring, clamp, plate, and the like.
Alternate Parts: PWA72121, 4920-01-468-3017, 01-468-3017, 4920014683017, 014683017
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 49 | OCT 05, 1999 | 01-468-3017 | 37032 ( MASK, PLASMA SPRAY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4920-01-468-3017
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| PWA72121 | 77445 | UNITED TECHNOLOGIES CORPORATIONDBA PRATT WHITNEY-SPARE PARTS |
Technical Data | NSN 4920-01-468-3017
| Characteristic | Specifications |
|---|---|
| OVERALL DIAMETER | 34.000 INCHES NOMINAL |
| END ITEM IDENTIFICATION | F100-PW-229 |
| FUNCTIONAL DESCRIPTION | FIXTURE IS REQUIRED TO HOLD AND ADAPT THE FAN CASE ASSY ONTO PWA71480 PEDESTAL IN A PLASMA SPRAY BOOTH. USED WITH PWA72124/72125 MASKS WHEN COATING 2ND STAGE VANE RAIL, OR WITH PWA72122/72123 MASKS WHEN COATING 3RD STAGE VANE RAIL, OR WITH PWA72167 MASK WHEN COATING THE CASE FRONT SNAP DIAMETER; TASK 310-66Y |
| REFERENCE DATA AND LITERATURE | F33657-97-C-0017, SERD 8712 |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | FIXTURE,PLASMA SPRAY-FAN CASE ASSY, 2ND AND 3RD STAGE RAILS |